| 加工定制: |
|
类型: |
工业冷水机 |
| 结构类型: |
|
标准制冷量(kw): |
|
| 输入功率(kw): |
|
外形尺寸: |
|
| 重量(kg): |
|
应用领域: |
|
DNC-AL风冷式低温冷冻机参数表
型号 项目 温度 使用 DNC-3AL DNC-5AL DNC-6AL DNC-8AL DNC-10AL DNC-12AL DNC-15AL DNC-20AL DNC-25AL DNC-30AL DNC-40AL
名义制冷量 "KW
50HZ/60HZ" -10℃ "3.8
4.6" "6.3
7.6" 7.5 9 "9.1
10.9" "13.2
15.8" "16.1
19.3" "19.5
23.4" "26.4
31.7" "32.2
38.6" "39
46.8" "52
62.4"
-20℃ "1.9
2.3" "3.0
3.6" 4 4.8 "6
7.2" "7.1
8.5" "8
9.6" "13.9
16.7" "16.9
20.3" "20.8
25" "24.4
29.3" "30.8
37"
-30℃ "1.0
1.2" "1.6
1.9" 1.9 2.3 "2.7
3.2" "3.2
3.8" "3.8
4.6" "6.1
7.3" "9.5
11.4" "12.1
14.5" "14.3
17.1" "19
22.8"
-35℃ "0.67
0.8" "1.04
1.25" 1.5 1.8 "2.3
2.8" "2.8
3.4" "3
3.6" "4.3
5.2" "6.35
7.62" "8.3
10" "10.1
12.1" "13.35
16"
蒸发器 冷冻水量(m3/h) -10℃ 0.65 0.79 1.1 1.3 1.3 1.5 1.6 1.9 2.3 2.7 2.8 3.3 3.4 4.1 4.5 5.4 5.6 6.7 6.7 8.1 9 10.8
-20℃ 0.33 0.4 0.52 0.62 0.69 0.83 1.1 1.3 1.23 1.47 1.38 1.65 2.39 2.87 2.85 3.45 3.57 4.3 4.2 5.04 5.3 6.36
-30℃ 0.17 0.21 0.28 0.33 0.33 0.4 0.47 0.55 0.55 0.65 0.65 0.8 1.1 1.3 1.6 2 2.1 2.5 2.46 2.9 3.3 3.9
-35℃ 0.12 0.14 0.18 0.22 0.26 0.31 0.4 0.48 0.48 0.58 0.52 0.62 0.72 0.89 1.1 1.31 1.43 1.72 1.74 2.09 2.3 2.76
类型 干式壳管式/不锈钢板换
进出水管径 lnch 1" 1" 1" 1" 1-1/2" 1-1/2" 2" 2" 2" 2-1/2" 2-1/2"
输入总功率 KW 3.18 4.86 5.61 7.25 9.4 10.9 13.5 18.8 22.55 28.5 37.5
最大运行电流 A 7.8 12 13.7 18 23 26.5 33 46 55 69 91
电 源 3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ)
制冷剂 名称 R22(R404A/R507)
控制方式 外平衡式热力膨胀阀
压缩机 类型 全封闭涡旋式(活塞式)
功率(KW) KW 2.25 3.75 4.5 6 7.5 9 11.3 7.5*2 9.37*2 11.3*2 30
冷凝器 类型 高效紫铜管套铝翅片式+低噪音外转子风机
水泵 功率 KW 0.75 0.75 0.75 0.75 1.1 1.1 1.5 2.2 2.2 4 5.5
最高扬程 m 20 20 20 20 20 20 20 20 20 25 20
安全保护 压缩机过热保护,过流保护,高低压力保护,超温保护,流量保护,相序/缺相保护,排气过热保护,防冻保护
机械尺寸 长 mm 980 11500 1500 1860 2020 2020 2200 2350
宽 mm 520 560 560 680 760 760 850 950 950 1150 1350
高 mm 11530 1660 1660 1900 2000 2000 1980 2000
机械重量 Kg 135 165 210 310 450 530 750 835 920 1080 1125
"?湓]:1.?冷量是依??豪?s?出??囟?0℃/38℃,冷?鏊?M出水?夭?℃至8℃,冷凝?囟仍?0℃。
2.冷凝?囟炔桓哽?5℃?境使用。
上述?格??党叽缛缬凶?更,恕不另行通知。
"